Model UV-1200 Ultra Violet Sterilizer

picture of the Wyckomar UV1200 Sterilizer

P1200/QD4E-1/2

The UV-1200 is a robust, high quality ultraviolet sterilizer designed for the disinfection of drinking water in the larger house where there is a 1" line, at a flow range between 13.2 and 33 GPM (50 - 125 LPM). Typically installed at the point of entry, it can treat municipal water as well as ground water from drilled or dug wells, and surface water from lakes, ponds or rivers. Other applications for this sterilizer are for the purification of drinking and process water in small commercial applications.

The UV-1200 sterilizer will purify the water from most common contaminants. Bacterial, viral and other pathogens are inactivated by a high intensity UV dose that kills harmful microorganisms such as E. coli and Giardia at a 99.99% kill rate.

  • Flow Range: 13.2 - 33 GPM / 50 - 125 LPM

  • Chamber Material: 304L SS (316L SS available)

  • UV Dose (95% UVT):
    16 mJ/cm2 at 33 GPM / 125 LPM,
    30 mJ/cm2 at 18 GPM / 68 LPM,
    40 mJ/cm2 at 13.2 GPM / 50 LPM

  • Monitoring System: Optional

  • Electronic Ballast w/ Operation Count: 4-BE800-ECO

  • UV Replacement Lamp: RL-84/893T5

  • Replacement Quartz Dome: RQD-895

  • Plumbing: 1" MNPT In/Out (25 mm BSP optional)


More info (Specifications Sheet, Technical Drawing, Technology Overview) can be downloaded here

specs icon Spec Sheet   drawings icon Tech Drawing   description icon UV Technology Info  


Pathogens that are inactivated by this UV sterilizer:
Anthrax, Chlorella, Clostridium, Coxsackie, Cryptosporidium parvum, E. coli, Giardia lamblia, Hepatitis, Influenza, Legionella, Listeria, Micrococcus, Paramecium, Polio, Pseudomonas, Salmonella, Shigella, Streptococcus, Toxoplasma, Vibrio cholerae
and many more. (See comprehensive UV Inactivation Chart)